FIRE TESTING
According to current codes and NER-467, panels made with a foamed plastic core
must be covered with a 15-minute thermal barrier. This is
defined as Y2" gypsum board or equivalent. Equivalent materials could be 5/8"
plywood or 1" x 6" T&G. In any event, seek approval on all
equivalent materials from local code officials. The Design U532 classification applies
to w. H. Porter, Inc., exclusively. Specific instructions relative to
installation of Type C gypsum board, use of dimensional lumber splines and joint
sealing must be followed.
Fire Resistance Ratings - ANSI/UL 263BXUVDesign No. U532
|
General Type "A" SIP Panel 38-001 Panel to Panel w/2x Lumber 38-102 Panel to Panel Floor Joist 38-104 Panel to Panel w/Insul Spline 38-106 Bearing Wall to Joist Multi-Story 38-203 Roof to Wall Beveled Seat 38-301 Roof to Wall Canted Plate 38-302 Roof Ridge w/Solid Blocking 38-303 Cantilever Roof Ridge w/Solid Blocking 38-304 Roof Ridge Connection w/EPS insert 38-306 Roof Eave on Pitched Roof 38-307 Roof to Wall on Gable Roof 38-308 Roof Ridge w/o Solid Blocking 38-312 Single Plate Insulated Headers 38-501 Double Plate Insulated Headers 38-502 Reinforcement of Field-Cut Wall Openings 38-503 Framed Roof Penetration 38-504 Unframed Roof Penetration 38-505
|
|