  Transverse Roof & Floor Panel Load Chart  

General Specifications

Code Listing by NTA

Transverse Roof & Floor Panel Load Charts

Transverse & Axial Wall Load Charts

Racking Load Charts

Header Load Charts

Fire Ratings

Energy Efficiency

 

Commercial Applications

Institutional Applications

Residential Applications

 

Transporting SIPs

Lifting & Rigging SIP

Recommended Tools

Accessories

Storing SIPs on Site

SIP Panel Numbering

Installing 1st & 2nd Panels

Field Cutting SIPs

Installing SIPs Headers

Installing SIPs Sill Plates

Drawing Panels Together

SIPs Moisture Protection

SIPs Temperature Warning

SIPs Wiring Considerations

SIPs Plumbing Considerations

SIPs HVAC Considerations

 



 Allowable Uniform Transverse Loads4

Panel Length

(ft)

4-5/8-inch Thick SIP

6-1/2-inch Thick SIP

Deflection Limit2

Deflection Limit2

L/180

L/240

L/360

L/180

L/240

L/360

8 WAB3

50.8

44.6

29.7

75.8

71.0

47.3

8

76.4

57.3

38.2

104.8

94.0

62.7

10

50.4

37.8

25.2

80.6

64.5

43.0

12

34.6

26.0

17.3

61.0

45.8

30.5

14

24.6

18.4

12.3

44.5

33.4

22.3

16

--

--

--

33.2

24.9

16.6

18

--

--

--

25.3

19.0

12.7




 Allowable Uniform Transverse Loads (continued)4

Panel Length

(ft)

8-1/4-inch Thick SIP

10-1/4-inch Thick SIP

12-1/4-inch Thick SIP

Deflection Limit2

Deflection Limit2

Deflection Limit2

L/180

L/240

L/360

L/180

L/240

L/360

L/180

L/240

L/360

8 WAB3

99.1

96.2

64.1

125.9

125.4

83.6

139.6

139.6

103.2

8

115.4

115.4

86.5

127.4

127.4

114.3

139.6

139.6

139.6

10

87.9

87.9

60.8

95.7

95.7

82.0

103.4

103.4

103.4

12

70.9

66.2

44.1

76.6

76.6

60.6

82.1

82.1

77.8

14

59.5

49.2

32.8

63.9

63.9

45.9

68.1

68.1

59.7

16

49.8

37.4

24.9

54.8

53.0

35.3

58.1

58.1

46.6

18

38.5

28.9

19.2

48.0

41.5

27.7

50.7

50.7

36.9

20

30.2

22.7

15.1

40.7

33.0

22.0

45.0

44.3

29.6

1 Table values assume a simply supported panel with 1.5-inches of continuous bearing on facing at supports (Cv = 1.0) with splines at bearing locations.  Values do not include the dead weight of the panel.  Cv=0.4 Shall be used where no bearing is provided.

2 Deflection limit shall be selected by building designer based on the serviceability requirements of the structure and the requirements of adopted building code. Deflection values based on loads of short duration only and do not consider effects of creep.

3 Tabulated values are based on the strong-axis of the facing material oriented parallel to the span direction.  WAB indicates weak-axis bending of the facing material (i.e. the facing material weak-axis is parallel to the span direction).

4Permanent loads, such as dead load, shall not exceed 0.50 times the tabulated load.

General Type "A" SIP Panel 38-001

Panel to Panel w/2x Lumber 38-102

Panel to Panel Corner 38-103

Panel to Panel Floor Joist 38-104

Panel to Panel w/Insul Spline 38-106

Panel on Slab 38-201

Bearing Wall to Joist Multi-Story 38-203

Panel on Sub Floor 38-204

Roof to Wall Beveled Seat 38-301

Roof to Wall Canted Plate 38-302

Roof Ridge w/Solid Blocking 38-303

Cantilever Roof Ridge w/Solid Blocking 38-304

Roof Ridge Connection w/EPS insert 38-306

Roof Eave on Pitched Roof 38-307

Roof to Wall on Gable Roof 38-308

Framed Roof Eave 38-309

Roof Valley Connection 38-310

Roof to Wall 38-311

Roof Ridge w/o Solid Blocking 38-312

Single Plate Insulated Headers 38-501

Double Plate Insulated Headers 38-502

Reinforcement of Field-Cut Wall Openings 38-503

Framed Roof Penetration 38-504

Unframed Roof Penetration 38-505

   