When a crane is to be used to lift a panel into
position, care must be taken in rigging the panel to avoid crushing the
edges of the OSB.
One method
is to drill a hole through the panel and insert a large eyebolt of
sufficient capacity to safely support the load, using large washers to
avoid pull-through. Following installation, the hole should be filled
(sealed) with expansion foam. Another method is to use a fixture, with
attachment point(s), which screw onto the panel. These fixtures are
available for loan or can be fabricated, ask the factory for details. Use
normal caution when lifting panels, keep all personnel clear of the overhead
load. Always use one or two tag lines to control the orientation of the
panel. Avoid lifting panels under windy conditions.
|
 |
|